Viconics VT7607 Echelon Integration Guide Manuale Utente Pagina 2

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 22
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 1
2
Product Overview
The VT76x7 PI thermostat family is specifically designed for single stage
and multi-stage control of heating/cooling equipment such as rooftop and
self-contained units with humidifier and/or dehumidifier. The product
features an embedded complete humidity solution with an intuitive, menu-
driven, backlit LCD display that walks users through the programming steps,
making the process extremely simple. Accurate temperature & relative
humidity control is achieved due to the product’s PI time proportional control
algorithm, which virtually eliminates temperature offset associated with
traditional, differential-based thermostats.
All models contain one digital input, which can be set by the user to monitor
filter status, activate a remote temporary occupancy switch, and/or used as
a general purpose service indicator. The two models contain a SPST auxiliary switch, which can be used to
control lighting or disable the economizer function and a discharge air sensor input.
The thermostats are also compatible with the new Viconics PIR cover accessories. Thermostats equipped
with a PIR cover provide advanced active occupancy logic, which will automatically switch occupancy levels
from Occupied to Stand-By and Unoccupied as required by local activity being present or not. This advanced
occupancy functionality provides advantageous energy savings during occupied hours without sacrificing
occupant comfort. All thermostats can be ordered with or without a factory installed PIR cover.
The additional following documentation is available on www.viconics.com
- Detailed information on the thermostat (VT76x7X5x00) is available in document LIT-VT76x7-PIR-Exx
- PIR application information and examples, are available on document: APP-VT76-PIR-Guide-Exx
- PIR cover installation information is available on document: PIR Cover Installation-Exx
Contents
PID History Revision Table
Thermostat Objects
SNVTs and SCPTs Table Per Model
Input Network Variables (nvi’s) Description
Output Network Variables (nvo’s) Description
Configuration Properties (nci’s) Description
Integration - Global Commands
Integration - Graphic User Interface (GUI) Objects
Integration - Configuration Objects
Wiring Guide
o Overview
o Network Configuration
o Maximum Number Of Devices
o Maximum Cable Length
o Repeaters
o Terminators
Network Adapter
Software Files
RoHS and Non-RoHS APB and NXE Files
Device Identification
Tips And Things You Need To Know
Troubleshooting Section
Document Control
F
ig.1 VT76x7B Thermosta